- Status of rig: Continued maintenance. Silver
paint applied to contact surfaces of VPT cans, some damaged cables repaired. MS/KWB
studying pulse shapes and earthing. E1/E6/E7/E8 all look strange, and all on same
amplifier card - this card has been changed. E5 led plate changed to reduce output
level.